Sprinkler, standpipe, suppression and smoke control design for large commercial, high-rise and existing-building projects — drawn to the standards Inspectional Services and the Boston Fire Department actually review against, and coordinated with the structural and MEP from the same firm.
Sprinkler · standpipe · suppression · smoke control · fire alarm · life safety
Designed against the standards a reviewer will open, not summarised from them.
Sprinkler systems to NFPA 13, standpipes to NFPA 14, fire pumps to NFPA 20 — with hydraulic calculations prepared, not assumed from a density chart.
Fire alarm design to NFPA 72, coordinated with the suppression design so the two sets agree before review rather than after a comment letter.
Atrium and high-rise smoke control to NFPA 92, with the special inspection and commissioning requirements written into the set rather than discovered later.
Occupant load, egress capacity and travel distance under NFPA 101 and 780 CMR — written as an analysis a reviewer can follow line by line.
Two departments review it, and the building stock is older and taller.
Tenant work in an existing tower, tying into base-building systems designed decades ago to a different code.
Warehouse to assembly, office to laboratory. The hazard classification changes, and the required sprinkler density with it.
Mill and masonry conversions, where the existing structure constrains every routing and penetration decision.
What a building would need before you buy it, established in time to affect the offer rather than after it.
Fire protection design is prepared by a licensed Professional Engineer holding a master’s degree in fire protection engineering — sprinkler, suppression and alarm — registered in Massachusetts among other states, with large commercial experience.
Structural and civil design by George Atallah, P.E., Massachusetts No. 53522, also registered in New Hampshire, Rhode Island and Connecticut.
Most fire protection drawings in Massachusetts are produced by mechanical engineers, or by the sprinkler contractor after the fact. An engineer who studied the discipline is a different proposition — and it is a fact you can weigh rather than a claim you have to take on trust.
Sprinkler mains and structural framing occupy the same ceiling. When those are drawn by two firms, the clash is found on site. Here they are drawn alongside each other and resolved before the set is issued.
Send us the scope and we will tell you what Inspectional Services and Boston Fire will each want to see — before you commit to anything.